응용 분야 및 기법
- 8.000.6048Fully automated determination of fluoride in blood samples
Sodium fluoride is used as a preservative in biological samples for alcohol analysis. All submitted blood samples, including those taken from vehicle drivers suspected of driving under the influence of liquor, have to be tested for adequate preservation prior to alcohol determination by gas chromatography. This is critical to ensure adequate sample preservation. Inadequate sample preservation may allow glycolysis and/or microorganism growth to produce ethanol.In the past this has been done by direct potentiometric measurement using a fluoride-selective electrode (F ISE), an ion meter and certified NaF standards. The sodium fluoride level was determined manually by dipping the electrode directly into the blood sample. Results were recorded manually. This poster describes two independent automated methods of analysis that allow the minimization of this tedious and time-consuming procedure.In the first one, the fluoride content in a blood aliquot is measured by direct potentiometric measurement after the addition of TISAB and deionized water. The second method employs the titration of the sample aliquot with La(NO3)3 after adding a buffer solution.
- 8.000.6057Simultaneous determination of gamma-hydroxybutyric acid (GHB) and gamma-butyrolactone (GBL) in beverages
Psychoactive gamma-hydroxybutyrate (GHB) and its prodrug gamma-butyrolactone (GBL) are substances that are increasingly abused as date-rape and recreational (party) drugs. Since the non-controlled GBL converts into the illicit GHB both in-vivo and in-vitro, their legal distinction is of crucial importance.For the forensic determination of illegally added GHB and GBL in commonly consumed beverages, this work presents a simple and sensitive method that employs direct-injection ion chromatography combined with spectrophotometric detection. The method allows to trace GHB-GLB interconversion, whether in vivo or in vitro lactone cleavage or intramolecular GHB esterification, and thus complies with pertinent requirements of law enforcement agencies.
- 8.000.6063Post-column chemistry for improved optical absorption detection
UV/VIS detection is one of the most sensitive detection techniques in trace-level chromatography. Sometimes, however, spectrophotometric detection lacks sensitivity, selectivity or reproducibility and chemical derivatizations are required. By using Metrohm`s rugged and versatile flow-through reactor, single- or multi-step derivatizations can be done fully automatically, in either pre- or post-column mode at any temperature between 25…120 °C. The variable reactor geometry allows to adjust the reactor residence time of the reactants according to derivatization kinetics. The flexibility of the reactor is demonstrated by optimizing four widespread post-column techniques: the relatively slow ninhydrin reaction with amino acids and the fast derivatizations of silicate, bromate and chromate(VI).
- AB-082Determination of fluoride with an ion-selective electrode
This Bulletin describes fluoride determination in various matrices with the help of the ion-selective fluoride electrode (F-ISE). The F-ISE is comprised of a lanthanum fluoride crystal and exhibits a response in accordance with the Nernst equation across a wide range of fluoride concentrations.The first part of this Bulletin contains notes regarding the handling and care of the electrode and the actual fluoride determination itself. The second part demonstrates the direct determination of fluoride with the standard addition technique in table salt, toothpaste and mouthwash.
- AB-083Sodium analysis by ion-selective electrode
This document explains how to measure Na ion concentration in diverse matrices with a sodium ion-selective electrode (Na-ISE) using direct measurement and standard addition.
- AB-213Determination of nicotinamide by polarography
This Application Bulletins describes the determination of nicotinamide (vitamin PP), a vitamin of the B series. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linearity range of the determination is also specified. The limit of detection is approximately 50 μg/L nicotinamide.
- AB-215Determination of folic acid by polarography
This Application Bulletin describes the polarographic determination of folic acid, a vitamin of the B series, also known as vitamin B9 or vitamin BC. Instructions for the determination in solutions (e.g. fruit juice), vitamin capsules and multivitamin tablets are given. The linear range of the determination is also specified. The limit of detection is approx. 75 µg/L folic acid.
- AB-218Determination of thiamine (vitamin B1) by polarography
This Application Bulletins describes the polarographic determination of thiamine (vitamin B1). The procedure allows an analysis in monovitamin preparations. The linear range of the determination is also given. The limit of detection is approx. 50 µg/L thiamine.
- AB-219Determination of riboflavin (vitamin B2) by polarography
This Application Bulletin describes the polarographic determination of riboflavin (vitamin B2). The procedure allows an analysis in monovitamin preparations. The limit of determination is approx. 100 μg/L.
- AB-220Determination of platinum and rhodium in the ultratrace range by adsorptive stripping voltammetry
This Application Bulletin describes …
- AB-250Polarographic determination of diazepam in body fluids and pharmaceutical preparations
Diazepam belongs to the 1,4-benzodiazepine group of compounds, which are used for medical purposes as tranquilizers and antidepressants. This Bulletin describes the determination of diazepam in tablets and body fluids (blood, serum, urine) by means of differential pulse polarography. If a Britton-Robinson buffer pH = 2.8 with a methanol volume fraction of 20% is used as the supporting electrolyte then a pronounced reduction peak is obtained at -0.73 V; this allows diazepam concentrations even below 0.05 µg/mL to be determined in blood. The necessary sample preparation steps are also dealt with in this Bulletin.
- AB-304Titration of whole blood and blood plasma for acid-base analysis according to Joergensen and Stirum
The presented Application Bulletin describes the apparatus and methods that are used for acid-base analysis of whole blood and blood plasma by Joergensen and Stirum. Evaluation of the measured data is performed with a software sold by Komstar AG.
- AN-CS-009Leaching tests for sample vials in cation trace analysis with sequential suppression
Sequential suppression in cation chromatography significantly improves detection limits. The determination of the blank value of the sample vial being used is thus essential for being able to achieve such low detection limits. The leaching tests of various sample vials proceed with the intelligent Preconcentration Technique with Matrix Elimination on the Metrosep C Supp 1 - 250/4.0 column with conductivity detection following sequential suppression. The 50 mL Corning® Cell Culture Flasks from Sigma-Aldrich (CLS430168) exhibit the lowest blank values.
- AN-FLU-002Understanding the mechanism of a bioassay indicator by fluorescence
Alamar Blue is monitored with fluorescence spectroelectrochemistry during its irreversible reduction to resorufin and further reversible reduction to dihydroresorufin.
- AN-I-025Purity of lucigenin by nitrate determination – Fast and inexpensive determination by standard addition
Lucigenin is one of the most often used chemiluminescent reagents and might be used for e.g., the indication of the presence of superoxide anion radicals.Lucigenin is rather expensive to buy, however, its synthesis only includes a two stage synthesis starting from acridanone. The first stage includes an Nmethylation, the second forms the lucigenin chloride, which is finally transformed into lucigenin nitrate. To check the purity of the synthesized lucigenin, ion measurement can be applied using a nitrate selective electrode. This is a fast and inexpensive method compared to competing methods such as ion chromatography.
- AN-NIR-019Human stool analysis by near-infrared spectroscopy
This Application describes the determination of moisture, nitrogen, and fat in stool samples using near-infrared spectroscopy. These parameters are of great importance in medical diagnostics.
- AN-O-027Citrate, succinate, lactate, β-hydroxybutyrate, and acetate in dry albumin powder using dialysis for sample preparation
Determination of citrate, succinate, lactate, β-hydroxybutyrate, and acetate in dry albumin powder using ion-exclusion chromatography with suppressed conductivity detection and dialysis for inline sample preparation.
- AN-P-063Mannitol, rhamnose, lactulose and lactose in blood serum with pulsed amperometric detection (PAD)
The lactulose/rhamnose (L/R) intestinal permeability test is used for the diagnosis of dysfunctional intestinal permeabilities. This test comprises the determination of mannitol, rhamnose, lactose and lactulose in addition to the usual blood sugars, e.g. glucose, galactose and saccharose. This Application Note presents the analysis of a blood plasma sample enriched with the four sugars mentioned above.Key word: leaky gut syndrome
- AN-RA-008Easy detection of enzymes with the electrochemical-SERS effect
Low sensitivity has limited the use of Raman spectroscopy as a detection method. However, the surface-enhanced Raman scattering (SERS) effect has improved its effectivity for analytical use. Aldehyde dehydrogenase (ALDH) and cytochrome c are analyzed by Raman spectroelectrochemistry as a proof of concept in this Application Note.
- AN-S-075Four anions in glutamine monofluorophosphate
Determination of fluoride, chloride, phosphate, and monofluorophosphate in glutamine monofluorophosphate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-090Four anions in a protein formulation using dialysis for sample preparation
Determination of chloride, nitrate, phosphate, and sulfate in a protein formulation using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-127Five anions in human urine
Determination of chloride, nitrate, phosphate, sulfate, and oxalate in human urine using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-143Glycerophosphates in amino acids
Determination of α-glycerophosphate and β-glycerophosphate in amino acids using anion chromatography with conductivity detection after chemical suppression.
- AN-S-179Six anions in a peptide sample
Determination of fluoride, chloride, bromide, nitrate, sulfate, and trifluoroacetate (TFA) in a peptide sample using anion chromatography with conductivity detection after chemical suppression.
- AN-S-188Chloride in children's sweat
Determination of chloride in a child's sweat using anion chromatography with conductivity detection after chemical suppression.
- AN-S-194Iodide in human urine
Determination of iodide in a human 24 hour urine sample using anion chromatography with amperometric detection after chemical suppression. The result agrees with that of the photometric method. UV detection did not work.
- AN-S-210Oxalate and citrate in human urine
Determination of oxalate and citrate in human urine using anion chromatography with conductivity detection after chemical suppression.
- AN-S-215Qualitative determination of anions in urine to verify adulteration
Qualitative determination of chloride, phosphate, and sulfate as well as chlorite, nitrite, chlorate, bromide, and chromate in urine using anion chromatography with conductivity detection after chemical suppression.
- AN-S-221Sulfate, phosphate, and pyrophosphate in human and mice urine
Determination of sulfate, phosphate, and pyrophosphate in human urine and mice urine using anion chromatography with conductivity detection after chemical suppression.
- AN-S-232Chloride and sulfate in electrolytes used in sensors for transcutaneous CO2 measurement
Determination of chloride and sulfate in an electrolyte used in sensors for transcutaneous CO2 measurement using anion chromatography with conductivity detection after chemical suppression.
- AN-T-083Photometric titration of chondroitin sulfate according to Ph. Eur. and USP
This Application Note details the photometric determination of chondroitin sulfate with 1-hexadecylpyridinium chloride as titrant and with the Optrode (660 nm). The method is in compliance with the Ph. Eur. and the USP.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- AN-U-054Amino acids applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
The determination of amino acid is an important task in pharmaceutical and biochemical applications. A binary gradient separates in this example 17 amino acids of a commercially available standard solution. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
- AN-U-055Amino acids in cell culture growth medium applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
Cell culture growth media contain all required components to keep cells alive. Here the amino acid composition is analyzed. A binary gradient separates in this example amino acids. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
- AN-V-044Boron in human plasma using Beryllon III as a ligand
Voltammetric determination of boron in plasma using Beryllon III as a ligand [L. Thunus (1996), Anal. Chim. Acta 318: 303–308].
- AN-V-096Platinum in urine after UV digestion
Platinum in urine can be determined by adsorptive stripping voltammetry (AdSV) after UV digestion of the sample.
- BWT-4909The Use of Raman Spectroscopy in the Field of Cancer Diagnostics
Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are proving to be invaluable tools in the field of biomedical research and clinical diagnostics. Raman systems are also being developed for molecular diagnostic testing to detect and measure human cancer biomarkers. This review highlights two applications realting to breast cancer and pancreatic cancer diagnosis together with examples of the use of Raman spectrometry in biomedical research areas such as the identification of bacterial infections, showing that Raman is an important part of the medical toolbox, as we continually strive to improve diagnostic techniques and bring a better health care system to patients.
- WP-008Coupling of ion chromatography and plasma mass spectrometry
The coupling of ion chromatography and inductively coupled plasma mass spectrometry (ICP/MS) leads to a high-performance measurement system that masters several particularly challenging analyses. It enables for example reliable determination of element compositions, oxidation states and chemical bonds. This information is used, for example, for assessing the toxicity of medications, environmental and water samples as well as foods and beverages.
- WP-058Virus detection: Fast, sensitive, and cost-effective with electrochemical testing
With significant global viral outbreaks becoming the norm rather than generational outliers, it is imperative that fast, sensitive, and cost-effective testing is available to the masses. Screen-printed electrodes (SPEs) allow rapid, widespread testing of populations for infectious disease, without the need of skilled personnel or burdensome equipment in the field. The possibility of point-of-care (POC) testing with SPEs has been exhibited in several recent studies. Metrohm DropSens combines high production capabilites of custom-made SPEs with a valid ISO 13485 certification "Manufacturing of sensors for medical devices", meaning testing procedures developed on these SPEs can be reliably scaled up for larger operations, with easier regulatory approval for commercialization.
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.