Uygulamalar
- 8.000.6063Post-column chemistry for improved optical absorption detection
UV/VIS detection is one of the most sensitive detection techniques in trace-level chromatography. Sometimes, however, spectrophotometric detection lacks sensitivity, selectivity or reproducibility and chemical derivatizations are required. By using Metrohm`s rugged and versatile flow-through reactor, single- or multi-step derivatizations can be done fully automatically, in either pre- or post-column mode at any temperature between 25…120 °C. The variable reactor geometry allows to adjust the reactor residence time of the reactants according to derivatization kinetics. The flexibility of the reactor is demonstrated by optimizing four widespread post-column techniques: the relatively slow ninhydrin reaction with amino acids and the fast derivatizations of silicate, bromate and chromate(VI).
- 8.000.6111Fully Automated Determination of pH Using Flow Cell Technology
A high throughput automated system was developed to determine pH of culture media using a pH module equipped with an external flow cell. A custom septum-piercing, vented needle was developed to accommodate the shape and size of the customer sample vials. For this application, both accurate and precise pH measurements were required. The data presented in this document was collected by a customer as a part of their validation process and was provided for use with their consent.
- AB-220Determination of platinum and rhodium in the ultratrace range by adsorptive stripping voltammetry
This Application Bulletin describes …
- AN-C-113Determination of lysine and standard cations in a lysine sample
Determination of lysine as well as sodium, ammonium, potassium, and calcium in bulk lysine using cation chromatography with direct conductivity detection.
- AN-CS-009Leaching tests for sample vials in cation trace analysis with sequential suppression
Sequential suppression in cation chromatography significantly improves detection limits. The determination of the blank value of the sample vial being used is thus essential for being able to achieve such low detection limits. The leaching tests of various sample vials proceed with the intelligent Preconcentration Technique with Matrix Elimination on the Metrosep C Supp 1 - 250/4.0 column with conductivity detection following sequential suppression. The 50 mL Corning® Cell Culture Flasks from Sigma-Aldrich (CLS430168) exhibit the lowest blank values.
- AN-FLU-002Understanding the mechanism of a bioassay indicator by fluorescence
Alamar Blue is monitored with fluorescence spectroelectrochemistry during its irreversible reduction to resorufin and further reversible reduction to dihydroresorufin.
- AN-N-051Acetate, chloride, citrate, and sulfate in a concentrate of an infusion solution containing amino acids and dipeptides
Determination of acetate, chloride, citrate, and sulfate in a concentrate of an infusion solution using anion chromatography with direct conductivity detection. Non-suppressed IC is used to avoid interferences by the amino acids.
- AN-P-064Separation of sugars and sugar acids using low-pressure gradient
A low-pressure gradient enables the separation of sugar acids strongly retained on the column and sugars within an appropriate analysis time. The saccharides are separated on a column of the Metrosep Carb 2 - 250/4.0 type with subsequent pulsed amperometric detection (PAD). Galactose and arabinose are not completely separated under the selected conditions.
- AN-P-065Sugar and sugar alcohols in addition to sucrose and cellobiose
This Application Note describes the separation of inositol, mannitol, glucose, xylose, fructose, lactose, sucrose and cellobiose on a column of the Metrosep Carb 2 - 150/4.0 type with subsequent pulsed amperometric detection (PAD).
- AN-P-077Proof of concept for the determination of lactose and its derivatives as well as sialic acid* in fermentation broths
The separation of lactose, lactobionic acid, sialic acid*, 6’-sialyllactose, and 3’-sialyllactose is shown as a proof of concept for the control of these components in fermentation process for a pharmaceutical product. The acceptance criterion of a minimum resolution of the peaks (< 1.3) is reached. The separation is achieved on a Metrosep Carb 2 - 250/4.0 column with subsequent pulsed amperometric detection.
- AN-PAN-1064Monitoring complexing agents in galvanic baths inline with Raman spectroscopy
Accurate analysis of complexing agents in galvanic baths is possible with inline Raman spectroscopy. This Application Note shows an example using a 2060 Raman Analyzer.
- AN-RA-008Easy detection of enzymes with the electrochemical-SERS effect
Low sensitivity has limited the use of Raman spectroscopy as a detection method. However, the surface-enhanced Raman scattering (SERS) effect has improved its effectivity for analytical use. Aldehyde dehydrogenase (ALDH) and cytochrome c are analyzed by Raman spectroelectrochemistry as a proof of concept in this Application Note.
- AN-S-075Four anions in glutamine monofluorophosphate
Determination of fluoride, chloride, phosphate, and monofluorophosphate in glutamine monofluorophosphate using anion chromatography with conductivity detection after chemical suppression.
- AN-S-090Four anions in a protein formulation using dialysis for sample preparation
Determination of chloride, nitrate, phosphate, and sulfate in a protein formulation using anion chromatography with conductivity detection after chemical suppression and dialysis for sample preparation.
- AN-S-143Glycerophosphates in amino acids
Determination of α-glycerophosphate and β-glycerophosphate in amino acids using anion chromatography with conductivity detection after chemical suppression.
- AN-S-179Six anions in a peptide sample
Determination of fluoride, chloride, bromide, nitrate, sulfate, and trifluoroacetate (TFA) in a peptide sample using anion chromatography with conductivity detection after chemical suppression.
- AN-SEC-002Gathering information from spectroelectrochemical experiments
In-situ spectroelectrochemistry provides dynamic electrochemical and spectroscopic information concurrently with the redox reaction occurring on the electrode surface. Although different spectroelectrochemical configurations can be used, simple equations explain how to relate electrochemistry and spectroscopy for each experimental setup. This Application Note describes how the quantification of one electrochemical parameter (the diffusion coefficient) is calculated from the spectroscopic data as a proof of this concept.
- AN-T-212FOS/TAC in fermentation substrate – Reliable determination for the monitoring of biogas plants
The FOS/TAC value, sometimes referred to as VFA/TA, is a meaningful parameter for assessing both the current condition and the development of anaerobic digestion processes in a digester of a biogas plant. Knowledge of this value can help decrease the risk of acidification problems, which can result in a costly crash of the entire digestion process. Therefore, an accurate and reliable determination of the FOS/TAC value is important for both efficient and cost-effective production operations. This value is determined by an acid-base titration. Using the Eco Titrator from Metrohm equipped with an Ecotrode plus electrode, a reproducible and accurate determination of the FOS/TAC value is possible.
- AN-T-227Determination of sodium lactate
Sodium lactate is a salt form of lactic acid used in many regulated industries—therefore an accurate determination of the lactate content is required and is already covered in several norms. One such monograph by the US Pharmacopoeia (USP) results in high accuracies and well-defined titration curves but uses titrants and solvents that are more costly than necessary. In comparison, the presented modified method from Metrohm requires a 1:1 mixture of water and acetone and uses aqueous hydrochloric acid as titrant, resulting in an estimated cost reduction of 40% per titration compared to the USP method (USP–NF 2021, Issue 2). Furthermore, the time needed for each analysis is reduced to just 12% of the USP method (excluding blank determination). This Application Note presents both methods to determine lactate content and shows the results obtained on an OMNIS system.
- AN-U-054Amino acids applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
The determination of amino acid is an important task in pharmaceutical and biochemical applications. A binary gradient separates in this example 17 amino acids of a commercially available standard solution. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
- AN-U-055Amino acids in cell culture growth medium applying UV/VIS detection after post-column reaction with ninhydrin at 120 °C
Cell culture growth media contain all required components to keep cells alive. Here the amino acid composition is analyzed. A binary gradient separates in this example amino acids. The post-column reaction with ninhydrin requires a temperature of 120 °C, while the samples need to be cooled for stability.
- AN-V-038Aluminum in albumin lyophilizate after digestion
Determination of aluminum with Eriochrome Blue Black R at 60 °C in albumin lyophilizate after a wet digestion.
- AN-V-060Cysteine and cystine in caseinate
Determination of cysteine and cystine in caseinate after sample preparation with NaOH.
- BWT-4913The Versatility of Portable Raman in Process Development
Raman spectroscopy is a well suited spectroscopic technique for process development and control within development laboratories in chemical, pharmaceutical, and other industries. This article demonstrates the utility of portable Raman spectroscopy as a simple and versatile tool for in situ monitoring of reactions using univariate analysis techniques such as peak trending, as well as multivariate analysis approaches to predict the end point of chemical reactions.
- WP-008Coupling of ion chromatography and plasma mass spectrometry
The coupling of ion chromatography and inductively coupled plasma mass spectrometry (ICP/MS) leads to a high-performance measurement system that masters several particularly challenging analyses. It enables for example reliable determination of element compositions, oxidation states and chemical bonds. This information is used, for example, for assessing the toxicity of medications, environmental and water samples as well as foods and beverages.
- WP-071Improving the corn to ethanol fermentation process with near-infrared spectroscopy (NIRS)
The fermentation of corn starch to produce ethanol is a complex biochemical process that requires monitoring of many different parameters (e.g., solids, pH, sugar profile, glycerol, lactic and acetic acid, and water and ethanol content). Traditional laboratory analysis using primary methods (e.g. Karl Fischer titration) takes about an hour to complete and is a limiting step for increasing plant capacity and efficiency. As a fast and non-destructive analytical technique, near-infrared spectroscopy (NIRS) can replace routine laboratory analysis, decreasing operating costs and increasing plant efficiency and capacity. This White Paper describes the capabilities of the modern analytical method near-infrared (NIR) spectroscopy for monitoring and improving the fermentation process of corn to ethanol.
- WP-086Measuring organic acids and inorganic anions with ion chromatography mass spectrometry
This White Paper focuses on selected IC-MS applications for the straightforward identification and quantification of organic acids and inorganic anions in different matrices.
- WP-097Why switch to OMNIS Client/Server (C/S)?
OMNIS Client/Server boosts business performance with scalable server management, cutting costs by reducing hardware, energy use, and maintenance across locations.