Ứng dụng
- 8.000.6063Post-column chemistry for improved optical absorption detection
UV/VIS detection is one of the most sensitive detection techniques in trace-level chromatography. Sometimes, however, spectrophotometric detection lacks sensitivity, selectivity or reproducibility and chemical derivatizations are required. By using Metrohm`s rugged and versatile flow-through reactor, single- or multi-step derivatizations can be done fully automatically, in either pre- or post-column mode at any temperature between 25…120 °C. The variable reactor geometry allows to adjust the reactor residence time of the reactants according to derivatization kinetics. The flexibility of the reactor is demonstrated by optimizing four widespread post-column techniques: the relatively slow ninhydrin reaction with amino acids and the fast derivatizations of silicate, bromate and chromate(VI).
- 8.000.6071Trace-level determination of anions in the primary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The poster presents the ion chromatographic determination of organic degradation products such as glycolate, formate and acetate besides the standard anions fluoride, chloride, nitrate and sulfate.
- 8.000.6072Trace-level determination of cations in the secondary circuit of a PWR-type nuclear power plant using ion chromatography after inline sample preparation
The presented IC system with inline sample preparation allows the determination of traces of lithium and sodium (ppt) in the presence of ppm quantities of ammonium and ethanolamine.
- 8.000.6091Ion chromatographic determination of halogens and sulfur in solids using combustion as inline sample preparation
The Combustion IC system presented allows the automated determination of organic halogen and sulfur compounds in all flammable samples. Both combustion digestion, which is automatically controlled with a flame sensor, and the professional Liquid Handling guarantee highest precision and trueness. This poster describes the determination of the halogen and sulfur content in a certified polymer standard, a coal reference material as well as in latex and vinyl gloves.
- AB-066Potentiometric and thermometric determination of boric acid
Boric acid is used in many primary circuits of nuclear power plants, in nickel plating baths, and in the production of optical glasses. Furthermore, boron compounds are found in washing powders and fertilizers. This bulletin describes the potentiometric and thermometric determination of boric acid. The determination also covers further boron compounds, when acidic digestion is applied.
- AB-223Fully automated determination of uranium
This Bulletin describes the fully automated determination of uranium according to the method of Davies and Gray: Uranium(VI) is reduced in concentrated phosphoric acid solution with iron(II) to form Uranium(IV). With molybdenum as a catalyst, the excess iron(II) is oxidized with nitric acid. The nitrous acid that is formed is destroyed with sulfamic acid before uranium(IV) is titrated with a potassium dichromate solution in the presence of a vanadium catalyst.
- AB-266Determination of titanium by adsorptive stripping voltammetry
This Application Bulletin describes the determination of titanium by adsorptive stripping voltammetry (AdSV) using mandelic acid as complexing agent. The method is suitable for the analysis of ground, drinking, sea, surface and cooling waters, in which the concentration of titanium is of importance. The methods can, of course, also be used for the trace analysis in other matrices. The limit of detection is approx. 0.5 µg/L.
- AN-C-049Trace cations in power plant feed water stabilized with 7 ppm monoethanolamine (MEA)
Determination of zinc, lithium, cobalt, sodium, ammonium, potassium, manganese, magnesium, and calcium in power plant feed water stabilized with 7 ppm monoethanolamine using cation chromatography with direct conductivity detection.
- AN-C-060Magnesium, strontium, and barium in produced water (11 g/L sodium)
Determination of magnesium, strontium, and barium in produced water using cation chromatography with direct conductivity detection.
- AN-C-083Online monitoring of trace levels of cations in boiler feed water
Determination of trace levels of lithium, sodium, ammonium, potassium, magnesium, and calcium in boiler feed water using cation chromatography with direct conductivity detection.
- AN-C-090Traces of zinc and iron(II) in the presence of the standard cations
Determination of traces of zinc and iron(II) in the presence of lithium, sodium, ammonium, potassium, calcium, and magnesium in boiler water using cation chromatography with direct conductivity detection.
- AN-C-096Trace analysis of monovalent cations in an ethanolamine matrix (secondary cycle of a pressurized water reactor) using Metrohm Inline Sample Preparation with an 800 Dosino for liquid handling
Methylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA) in methylpyrrolidone using Metrohm Inline Matrix Elimination.
- AN-C-126Methylamines and ethanolamines (Metrosep C 4 - 150/4.0)
Determination of monomethylamine (MMA), dimethylamine (DMA), trimethylamine (TMA), monoethanolamine (MEA), diethanolamine (DEA), and triethanolamine (TEA) using cation chromatography with direct conductivity detection.
- AN-C-132Traces of lithium, sodium, and ammonium in the presence of ethanolamine (Metrosep C 4 - 250/4.0)
Determination of lithium, sodium, ammonium, and monoethanolamine (MEA) using cation chromatography with direct conductivity detection and Metrohm Inline Preconcentration and Inline Calibration.
- AN-C-137Copper, nickel, zinc, and common cations in the water-steam cycle of a boiling water reactor (BWR)
Water chemistry of the water-steam cycle is crucial for maintaining plant reliability and for ensuring optimal plant operational conditions. Impurities such as corrosion products in ionic, colloidal, or oxide forms are ubiquitous in feedwater, condensate, and reactor coolant. This application shows the determination of sub-ppb levels of Cu, Ni, Zn and standard cations (e.g., Na +, NH 4+, Mg 2+, Ca 2+) in the water-steam cycle of a BWR.
- AN-C-138Zinc, nickel, calcium, and magnesium in borated water of a pressurized water reactor (PWR)
In pressurized water reactors (PWRs), light water is used as primary coolant. Boron (as boric acid) readily absorbs neutrons and is added to the coolant to control reactivity. Lithium hydroxide assures a pH value greater than 7 to prevent corrosion. This application allows to measure sub-ppb levels of zinc, nickel, calcium, and magnesium besides high boric acid and lithium hydroxide concentrations.
- AN-C-139Cations and amines in the water-steam cycle
Water in steel-based cooling systems requires a pH value slightly above 7 to prevent corrosion. Often ammonium or organic amines are applied for pH adjustement. This application shows the separation of typical amines besides inorganic cations. Sample preconcentration applies combined Inline Preconcentration and Matrix Elimination (MiPCT-ME).
- AN-C-140Lithium in borated water of a pressurized water reactor (PWR)
In pressurized water reactors (PWRs), light water is used as coolant in the primary side. Boron (as boric acid) is added to the coolant to absorb neutrons, thus controlling reactivity. Lithium hydroxide assures the alkaline pH value to prevent corrosion. This application allows to measure lithium content besides high boric acid concentrations. AN-C-138 shows the respective trace metal determination on the same system setup.
- AN-C-170N-methyldiethanolamine, piper-azine and standard cations in scrubber solutions
N-methyldiethanolamine and piperazine are used in scrubber solutions, e.g., in the natural gas process. Testing this type of samples by ion chromatography requires a good resolution and the separation of amines from standard cations. The separation is achieved on a Metrosep C 4 - 150/4.0 column applying direct conductivity detection.
- AN-C-171N-methyldiethanolamine and piperazine in scrubber solution
Before the liquefaction process of the natural gas, carbonate and hydrogen sulfide need to be removed through a scrubber solution containing piperazine and N-methyl diethanolamine (MDEA). The concentration ratio of the two components is determined by ion chromatography on a Metrosep C 4 - 150/4.0 column applying direct conductivity detection.
- AN-C-193Alkyl amines in scrubber solutions
Harmful industrial flue gases like H2S and CO2 cause corrosion of pipes and damage the environment. Adding the correct amount of amines in scrubber solutions, e.g. ethanolamines and methylamines, will neutralize these gases («gas sweetening»). Non-suppressed cation analysis with direct conductivity detection is a straightforward and robust technique for the quantification of monoethanolamine (MEA), diethanolamine (DEA), triethanolamine (TEA), monomethylamine (MMA), dimethylamine (DMA), and trimethylamine (TMA) via ion chromatography. Thanks to the high capacity of the Metrosep C 6 column, large volumes can be injected without compromising the peak shapes. The analytical technique can be used at laboratory scale but also for process analysis.
- AN-CIC-011Analysis of an ion exchanger using Metrohm Combustion IC
The manufacture of ultrapure water for the pharmaceuticals industry or the semiconductor industry requires high-quality ion exchangers. Metrohm Combustion Ion Chromatography is an indispensable tool in this connection for testing the purity of anion exchange material. The output sample was wet and had to be dried at 105 °C in a special oven with waste air evacuation. Keyword: pyrohydrolysis
- AN-CIC-016Halogen traces in coal with the Metrohm Combustion IC
The burning of coal contaminates the atmosphere with halogens. Fluorine and chlorine are natural components of coal, whereas the bromide that is found therein is often adulterated as calcium bromide in order to reduce mercury emissions. This Application Note shows the results of combustion digestion with Combustion IC for three coal samples, each with a different bromide content. Keyword: pyrohydrolysis
- AN-CIC-020Fluorine in coal sample applying Metrohm Combustion IC
Coal contains a certain amount of fluorine, chlorine, and sulfur compounds. During combustion of the coal, these components release corrosive acids (e.g., fluorine compounds form hydrofluoric acid). Thermal power plants therefore request low-fluorine coal to avoid massive hydrofluoric acid production. In this application note, fluorine content in coal is determined by ion chromatography after pyrohydrolysis.
- AN-CS-010Traces of lithium and sodium besides monoethanolamine in water-steam circuits of thermal power plants
Boiler feed water is a working medium in thermal power plant. To keep corrosion low, the pH value should be in the slightly alkali range, which is why amines are added to the feed water. This addition must be monitored regularly. Also important is the monitoring of the sodium concentration, because an increase of this indicates that cooling water is seeping into the condenser. Ion chromatography with conductivity detection following sequential suppression is the optimum system for monitoring, particularly in combination with intelligent Sample Preconcentration and Matrix Elimination.
- AN-H-012Determination of ferrous ion content of heat exchanger wash solutions
Determination of ferrous ions in heat exchanger and vessel acid wash solutions, for measuring the effectiveness of acid inhibitors used in the solutions. Depending on the condition of the sample, the lower practical limit for the determination will vary from approximately 20-100mg/Kg Fe2+. Samples with high silicic acid contents require relatively large amounts of dilution water to render them mobile, and this limits the aliquot size and hence the amount of Fe2+ which can be analyzed.
- AN-H-079Determination of free acid in heat exchanger cleaning acid
Determination of free acid in sulfuric acid («acid shot») solutions employed in the removal of silicate scale in heat exchangers. This method is suitable for acid shot solutions where the silicic acid content is so high that the solutions have gelled.
- AN-K-010Water in coal dust
The water content of coal dust is determined according to Karl Fischer. Because of the low water content of the voluminous sample, the oven method (nitrogen, 270 °C) and coulometric titration have to be used.
- AN-M-007Determination of urea in ultrapure water using IC-MS
Urea is not a typical analyte for ion chromatography. In combination with MS, however, IC is the method of choice for the trace analysis of urea in ultrapure water. This Application Note shows the determination of urea concentrations in the ppb range using the Metrosep C 6 - 250/4.0 column.
- AN-N-005Traces of silica (SiO2) in water (e.g., boiler water) after preconcentration
Determination of silica (as silicate) in pure water with preconcentration using anion chromatography with direct conductivity detection (without any post-column reaction).
- AN-N-058LOD and LOQ for silicate and borate determination according to EPA (MDL procedure)
Determination of silicate and borate and their limits of determination (LOD) and quantification (LOQ) according to the EPA procedure for method detection limit (MDL) using anion chromatography with direct conductivity detection and Metrohm Inline Calibration.
- AN-N-065Borate in borate effluent
Determination of borate in a borate effluent using anion chromatography with direct conductivity detection.
- AN-NIR-117Analysis of moisture, ash, carbon, and volatile content in coal by NIRS
Conventional methods used to analyze moisture, ash, fixed carbon, and volatile content in coal samples, are time consuming and costly. Near-infrared (NIR) spectroscopy is excellently suited to determine all parameters simultaneously in less than one minute without any sample preparation.
- AN-O-018Boric acid and acetic acid in process water
Determination of boric acid and acetic acid in process water using ion-exclusion chromatography with conductivity detection after chemical suppression.
- AN-P-058Amines in gas scrubber solutions using IC and pulsed amperometric detection
Scrubber solutions for scrubbing flue gas often contain amines for absorbing acid gases, e.g., sulfur dioxide (SO2). 1-(2-hydroxyethyl)piperazine and 1,4- Bis(2-hydroxyethyl)piperazine from gas scrubber solutions are separated in the Metrosep Carb 2 - 150/4.0 column and then determined using pulsed amperometric detection.
- AN-PAN-1003Online analysis of amines concentration in carbon capture plants
Carbon capture systems strip carbon dioxide from flue gases. Online analysis of amines and carbon dioxide enhances amine usage efficiency and reduces operational costs.
- AN-PAN-1013Phân tích trực tuyến axit boric trong nước làm mát của lò phản ứng nước áp suất
Axit boric yêu cầu giám sát chính xác trong mạch sơ cấp để kiểm soát tính phản ứng của lò phản ứng hạt nhân. Thiết bị 2060 TI Process Analyzer giám sát axit boric trực tuyến trong thời gian gần thực.
- AN-PAN-1015Calcium and sulfate in flue-gas desulfuration
This Process Application Note deals with the online monitoring of calcium and sulfate in flue gas scrubbing solutions using titration. Other contaminants that can be measured are sulfite, chloride, and chlorine. Low concentrations of heavy metals such as cadmium, zinc, copper, and lead can be measured in the ppb/ppm range with the ADI 2045VA Process Analyzer using voltammetry.
- AN-PAN-1016Online analysis of silica in boiler feed water of power plants
Excessive silica concentrations in the boiler feed water can lead to deposits on turbine blades and must therefore be avoided. Silica analysis is carried out via differential photometry using a leading-edge technology thermostatic cuvette module for non-sample contact at the detector. Typical concentration ranges for silica are 0–50 ppb and 0–1 ppm or higher.
- AN-PAN-1032Monitoring corrosion in power plants with online process analysis
Corrosion in the water-steam circuit of power plants leads to shorter lifetimes of most metal components and potentially dangerous situations. Flow Accelerated Corrosion (FAC) is a specific case, leading to thinned pipes and elevated Fe concentrations in the circuit. Additionally, metal transport issues such as with Cu from copper heat exchangers can lead to deposition on the high pressure turbine blades, decreasing their efficiency. Current methods can monitor but not prevent these issues, and analysis times are extremely long (up to three weeks). In combination with the power plant’s Distributed Control System (DCS), online monitoring of Fe and Cu with the 2060 Process Analyzer from Metrohm Process Analytics ensures that corrosion can be controlled before it affects the power plant efficiency, ultimately decreasing downtime and lowering maintenance costs. Results are offered within 20 minutes, allowing fast adjustments to the water-steam circuit to protect company assets.
- AN-PAN-1038Power generation: Analysis of the m value (Alkalinity) in cooling water
One way to maximize heat transfer efficiency and reduce costs in a power plant is by controlling the water chemistry in the cooling circuit. This cooling water is kept alkaline to maintain the protective oxide layer on the metal piping throughout the water circuit. However alkalinity above the recommended range increases the probability of scale formation (deposition), so it is buffered with carbonate (CO32-) and bicarbonate ions (HCO3-). Titration of the cooling water to pH 4.5 gives the so-called "M-Alkalinity" (methyl orange alkalinity), a measure of total alkalinity. Below this pH, there is no more alkalinity present, only free acid (H+), carbonic acid (H2CO3), and CO2.
- AN-PAN-1040Ammonia in cooling water of thermal power plants
Thermal power plants require enormous amounts of water, using high purity steam at high pressure to rotate turbines. A separate cooling water circuit is implemented, which helps to form a vacuum when the steam condenses after the turbines. Maintaining this vacuum with optimal condensation parameters is critical for the power plant efficiency. The copper condensers are susceptible to corrosion by ammonia, leading to an upper limit of 2 mg/L NH3 set by EPRI in cooling water. Small cracks in the condenser combined with the large pressure differential between the steam circuit and the cooling water circuit will contaminate the high purity water in the boiler, causing major problems and necessitating a shutdown for plant maintenance. Monitoring NH3 online in cooling water with a process analyzer can signal early problems in a plant before significant intermediation is necessary.
- AN-PAN-1042Phân tích trực tuyến vết các anion trong mạch sơ cấp nhà máy điện hạt nhân
Các biện pháp giám sát hoặc ngăn ngừa ăn mòn là rất quan trọng trong các nhà máy điện hạt nhân, nơi có thể xảy ra các rủi ro đáng kể đối với sức khỏe và an toàn nếu không kiểm soát ăn mòn. Các anion ăn mòn kim loại dưới nhiệt độ và áp suất cao, do đó, nồng độ của chúng phải luôn được theo dõi. Thách thức phân tích trong mạch chính là phát hiện các anion trong khoảng & mu; g / L cùng với lượng gam axit boric và liti hydroxit. Phân tích dấu vết chính xác, đáng tin cậy đòi hỏi phương pháp phải được tự động hóa hết mức có thể. Máy phân tích quá trình vi mạch 2060 của Metrohm Process Analytics có thể đo một số anion từ một lần bơm, với sự kết hợp của sự tập trung trước nội tuyến và loại bỏ ma trận nội tuyến để đo nồng độ anion thấp một cách chính xác và đáng tin cậy theo thời gian.
- AN-PAN-1043Online trace analysis of cations in the primary circuit of nuclear power plants
In power plants, corrosion is the primary factor leading to costly and critical downtimes. In a nuclear power plant, a separate water circuit known as the Pressurized Water Reactor (PWR) ensures radioactive material stays contained while still transferring heat and energy to the other circuits. Boric acid and lithium hydroxide are added specially to the PWR circuit in amounts which can complicate other analytical measurements. Lithium prevents corrosion and must be monitored, along with other cations such as zinc, nickel, and ammonium. In order to measure these cations online at sub-µg/L range in a single analysis, the 2060 IC Process Analyzer is offered with combined Inline Preconcentration and Inline Matrix Elimination. Several cations can be analyzed in a single injection, with automated sample preparation making precise and reliable measurements easier.
- AN-PAN-1044Online trace analysis of amines in the alkaline water-steam circuit of power plants
Neutralizing amines are added to adjust pH levels within the water-steam circuit of power plants to avoid corrosion-inducing conditions. This preventive maintenance can reduce costly and critical downtimes due to corrosion, however frequent monitoring of the amine chemistry is necessary to ensure conditions stay optimal. The 2060 IC Process Analyzer featuring the Metrohm intelligent Partial Loop Technique (MiPT) option is ideal for this application, with the ability to measure trace amounts of the analytes precisely and reliably through an automated method. The benefit of using IC is that multiple analytes can be monitored simultaneously, and here the ability to measure the presence of sodium next to the high ammonium or amine concentrations could indicate that cooling water is seeping into the circuit, indicating a problem upstream.
- AN-PAN-1045Online monitoring of copper corrosion inhibitors in cooling water
Copper is used widely in industrial cooling water systems for its heat transfer properties, although it is susceptible to corrosion. Corrosion can cause a loss of efficiency and eventually a failure of equipment, leading to costly maintenance, replacement, and downtime. Corrosion inhibitors (triazoles) can be added to the water chemistry, which form sparingly soluble protective layers on the surface of the metal. Triazole concentrations must be maintained to protect the copper, which necessitates regular concentration determinations in cooling water. The 2060 IC Process Analyzer with UV/VIS detection is well-suited for this application, able to precisely and reliably measure multiple ionic and UV-active compounds simultaneously in cooling water.
- AN-PAN-1056Online monitoring of sodium in industrial power plants
In power plants, corrosion is the greatest enemy. If corrosive impurities are present in the circuit streams (e.g., chlorides and hydroxides), deposition of an insulating layer of scale on the heat transfer surfaces occurs, resulting in costly and critical downtimes. To ensure high throughput of power plants, online analysis of critical parameters such as sodium is highly advantageous for safety, protection, and process optimization. With the 2035 Process Analyzer from Metrohm Process Analytics, operators gain the information they need to accurately identify trends, reduce downtimes, and address operational issues before costly problems arise.
- AN-PAN-1064Monitoring complexing agents in galvanic baths inline with Raman spectroscopy
Accurate analysis of complexing agents in galvanic baths is possible with inline Raman spectroscopy. This Application Note shows an example using a 2060 Raman Analyzer.
- AN-Q-003Online monitoring of trace levels of anions in boiler feed water
Determination of trace levels of chloride, nitrate, phosphate, and sulfate in boiler feed water using anion chromatography with conductivity detection after chemical suppression.
- AN-Q-004Online analysis of trace cations in power plant water matrices
A setup that allows online sampling is crucial for immediate and contamination-free analysis of power plant water samples. This application recommends a setup that facilitates simultaneous anion/cation determinations. Automated inline sample preparation combines variable preconcentration (MiPCT) and calibration with a single multi-ion standard. AN-Q-005 shows the respective anion results.
- AN-Q-005Online analysis of trace anions in power plant water matrices
A setup that allows online sampling is crucial for immediate and contamination-free analysis of power plant water samples. This application recommends a setup that facilitates simultaneous anion/cation determinations. Automated inline sample preparation combines variable preconcentration (MiPCT) and calibration with a single multi-ion standard. AN-Q-004 displays the respective cation results.
- AN-Q-006Online analysis of trace anions in borated water of a pressurized water reactor (PWR)
Water of the primary cycle of pressurized water reactors (PWR) contains boron for neutron absorption. The high borate content interferes with the direct analysis of trace anions. Inline Neutralization combined with variable preconcentration and Inline Matrix Elimination (MiPCT-ME) allows to remove boron as boric acid before injection.
- AN-Q-007Online analysis of chloride and sulfate in supercritical water-steam cycles
A combination of the 850 Professional IC and the 872 Extension Module Liquid Handling opens the field of Metrohm’s online monitoring by IC. In this application, Inline Preconcentration is coupled to Matrix Elimination (MiPCT-ME). By removing excess matrix components, corrosive anions can be sensitively determined. Additionally, this technique allows automated calibration using a single multi-ion standard solution. Online trace analysis for chloride and sulfate is possible for several different sample lines.
- AN-S-005Six anions in cooling water
Determination of fluoride, chloride, nitrite, nitrate, phosphate, and sulfate in cooling water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-032ppt analysis (ng/L) in ion chromatography
Determination of chloride, nitrate, and sulfate in ultrapure water after sample preconcentration using anion chromatography with conductivity detection after chemical suppression.
- AN-S-157Trace anions in boiler feed water containing 10 mg/L ammonia
Determination of traces of fluoride, chloride, bromide, nitrate, and sulfate in a boiler feed water containing 10 mg/L ammonia using anion chromatography with conductivity detection after chemical suppression and inline sample preparation by cation exchange.
- AN-S-206Online monitoring of trace anions in boiler feed water
Determination of trace levels of chloride, nitrate, phosphate, and sulfate in a boiler feed water using anion chromatography with conductivity detection after chemical suppression.
- AN-S-218Common anions in a closed cooling water system
Determination of fluoride, chloride, nitrite, nitrate, and sulfate in a closed cooling water system using anion chromatography with conductivity detection after chemical suppression.
- AN-S-222Anions in borate effluent
Determination of fluoride, chloride, nitrate, phosphate, and sulfate in a borate effluent using anion chromatography with conductivity detection after chemical suppression.
- AN-S-228Anions in perfluorocarbon
Determination of fluoride, chloride, nitrate, sulfate, and oxalate in a perfluorocarbon material using anion chromatography with conductivity detection after chemical suppression.
- AN-S-242Trace analysis of anions in the primary cycle of a nuclear power plant (PWR) using Metrohm Inline Sample Preparation
Determination of fluoride, glycolate, acetate, formate, chloride, nitrite, nitrate, and sulfate in the primary cycle water of a pressurized water reactor (PWR) using anion chromatography with conductivity detection after chemical suppression calibrated with Metrohm Inline Calibration.
- AN-S-295Anions in boiler water including sulfur speciation (sulfite and sulfate)
Boiler water analysis is an important task in power plant applications. Under the given conditions, the "Metrosep A Supp 10 - 100/4.0" column separates sulfite and sulfate without any organic modifier in the eluent. Even without any stabilizer, sulfite can be determined with a high reproducibility.
- AN-S-306Trace anions including chromate in water-steam cycle of a boiling water reactor (BWR)
Water of the water-steam cycle of boiling water reactors (BWR) needs to be free of corrosive anions. Analyzing these trace anions allows the parallel determination of chromate, which is a potential corrosion product. Automated sample preparation includes variable Inline Preconcentration (MiPCT) and automatic calibration with a single multi-ion calibration standard.
- AN-S-310Short-chain organic acid anions in addition to standard anions applying a Dose-in Gradient and MiPuT
Formate, acetate, propionate, and butyrate in addition to standard anions are determined in a coal extract. To improve the separation of the early eluting organic acid anions, a Dose-in Gradient is applied. Due to the limited sample volume available, Metrohm intelligent Pick-up Technique (MiPuT) is also utilized.
- AN-S-329Anions in FDG gypsum in accordance with VGB-M 701e (consultative document of European Technical Association for the Generation of Electricity and Heat)
FDG gypsum originates from flue gas desulfurization systems in power plants. VGB-M 701 E (2008) describes aqueous extraction methods for determining chloride in FDG gypsum using ion chromatography. The sample preparation described in the VGB permits the determination of other anions besides chloride.
- AN-T-027Alkalinity of amine-containing gas washing solutions
Determination of the alkalinity of gas washing solutions containing alkanolamines by potentiometric titration with sulfuric acid using the combined glass electrode.
- AN-T-201pH value of engine coolants or antirust
Corrosion of metallic components is an inherent problem for engines, because metals naturally tend to oxidize in the presence of water and/or acids. Increased acid content is indicated by a low pH value, and could lead to a variety of problems like a shorter storage life (stability) or a reduced buffer capacity of the used engine coolant or antirust. In this Application Note, engine coolants or antirust samples are dissolved in water, and the pH measurement using the Profitrode is carried out according to ASTM D1287.
- AN-T-202Reserve alkalinity of engine coolants
Corrosion of metallic components is an inherent problem for engines, because metals naturally tend to oxidize in the presence of water and/or low pH value. The reserve alkalinity of engine coolants and antirusts is a measure of the buffering ability to absorb acidity. The reserve alkalinity is frequently used for quality control during production and often listed in the specifications of the coolants. A fast and accurate determination is therefore important. This Application Note describes the straightforward determination of reserve alkalinity according to ASTM D1121. Using a fully automated system allows an accurate and reliable determination due to the reduction of human errors. Furthermore, the operator is free to carry out other tasks increasing the efficiency of the laboratory.
- AN-T-212FOS/TAC in fermentation substrate – Reliable determination for the monitoring of biogas plants
The FOS/TAC value, sometimes referred to as VFA/TA, is a meaningful parameter for assessing both the current condition and the development of anaerobic digestion processes in a digester of a biogas plant. Knowledge of this value can help decrease the risk of acidification problems, which can result in a costly crash of the entire digestion process. Therefore, an accurate and reliable determination of the FOS/TAC value is important for both efficient and cost-effective production operations. This value is determined by an acid-base titration. Using the Eco Titrator from Metrohm equipped with an Ecotrode plus electrode, a reproducible and accurate determination of the FOS/TAC value is possible.
- AN-U-059Transition metals in feedwater using post-column reaction and subsequent UV/VIS detection
Feedwater for steam generation in boiling water reactors (BWR) needs to be analyzed for corrosion products. Presence of transition metals, mainly nickel and iron, indicates corrosion problems. Traces of these ions are determined using Inline Preconcentration (MiPCT). After separation, post-column reaction with 4-(2-pyridylazo)resorcinol (PAR) allows VIS detection at 510 nm.
- AN-U-060Corrosion inhibitors in cooling water
In industrial cooling water systems, copper and its alloys are widely used because of their superior heat transfer properties. These materials are, however, susceptible to corrosion. Azoles are commonly used to protect copper and its alloys from corrosion. These corrosion inhibitors are quantified by ion chromatography with UV/VIS detection.
- AN-V-022Antimony and bismuth in an alkaline zinc oxide solution in one run
Simultaneous determination of Sb and Bi in an alkaline ZnO solution.
- AN-V-023Aluminum in an alkaline zinc oxide solution
Determination of Al in alkaline ZnO solution with Eriochrome Blue Black R at 60 °C.
- AN-V-061Iron speciation in water with the Multi-Mode Electrode pro
Accurate determination of Fe(II) and Fe(III) in water is crucial for many industries. Cathodic sweeping voltammetry (CSV) offers a robust, cost-effective solution.
- AN-V-179Iron in boiler feed water
The iron concentration in boiler feed water has to be monitored to ensure reliable and safe operation of the water-steam circuit. Various guidelines set limits for the maximum iron content. The concentration of total iron in boiler feed water can be determined with high sensitivity using adsorptive stripping voltammetry (AdSV) using 2,3- dihydroxynaphthalene (DHN) as complexing agent. Voltammetry is a viable, less sophisticated alternative to atomic absorption spectroscopy (AAS) or inductive couple plasma (ICP) for the determination of iron with only a moderate investment in hardware required and low running costs.
- WP-087Green alternative methods for voltammetric analysis in different water matrices
This White Paper presents four different «green» sensors: the scTRACE Gold, screen-printed electrodes, the glassy carbon electrode, and the Bi drop electrode from Metrohm that can be used to determine low concentrations of heavy metals in different sample matrices, such as boiler feed water, drinking water, and sea water.
- WP-097Tại sao chuyển sang OMNIS Client/Server (C/S)?
OMNIS Client/Server nâng cao hiệu suất kinh doanh nhờ khả năng quản lý máy chủ linh hoạt, giúp cắt giảm chi phí thông qua giảm phần cứng, tiêu thụ năng lượng và bảo trì tại nhiều địa điểm.