Ứng dụng
- AB-121Determination of nitrate with the ion-selective electrode
It has been known for years that consuming too much nitrates from foodstuffs can result in cyanosis, particularly for small children and susceptible adults. According to the WHO standard, the hazard level lies at a mass concentration c(NO3-) ≥ 50 mg/L. However, more recent studies have shown that when nitrate concentrations in the human body are too high, they can (via nitrite) result in the formation of carcinogenic and even more hazardous nitrosamines.Known photometric methods for the determination of the nitrate anion are time-consuming and prone to a wide range of interferences. With nitrate analysis continually increasing in importance, the demand for a selective, rapid, and relatively accurate method has also increased. Such a method is described in this Application Bulletin. The Appendix contains a cselection of application examples where nitrate concentrations have been determined in water samples, soil extracts, fertilizers, vegetables, and beverages.
- AN-C-121Strontium and barium in monoethylene glycol
Determination of strontium and barium in monoethylene glycol using cation chromatography with direct conductivity detection.
- AN-C-122Cations including total iron content in antifreeze (monoethylene glycol)
Determination of sodium, potassium, iron(II), magnesium and calcium in antifreeze (monoethylene glycol) using cation chromatography with direct conductivity detection. Ascorbic acid reduces iron(III) to iron(II). In this way total iron is determined as iron(II).
- AN-C-162Cationic components in developer solution applying a flow gradient
This Application Note describes the determination of N,N-diethylhydroxylamine (DEHA), triisopropanolamine (TIPA) and a cationic color developing component (CDC) in a developer solution. The analysis is performed on a high-capacity column such as Metrosep C - 250/4.0 with subsequent direct conductivity detection. To reduce the residence time of the strongly retained color developer components, the column flow rate is increased after the elution of the amines.
- AN-C-175Purity of 2-amino-N-(2,2,2-trifluoroethyl)-acetamide by ion chromatography
2-amino-N-(2,2,2-trifluoroethyl)-acetamide is a organic building block for synthesis of pharmaceutical products. Its purity is crucial for the success of the respective synthesis step. 2,2,2-trifluoroethylamine, glycine, and inorganic cations are of interest. Their total peak area is required to be < 2 % of the peak area of all peaks above the reporting level. Separation and quantification is achieved on a Metrosep C 4 - 250/4.0 cation column.
- AN-CS-012Determination of trimenthylamine and standard cations in 30% hydrogen peroxide (H2O2)
Hydrogen peroxide is available in different purity grades depending on its use. High purity H2O2 (electronic grade) requires very low contamination levels, e.g., less than 1 μg/L of trimethylamine (TMA). This application describes the determination of trimethylamine in a high-purity H2O2 solution (30%). Analysis is performed using Inline Preconcentration with Matrix Elimination (MiPCT-ME) applying conductivity detection after sequential cation suppression.
- AN-H-017Determination of bromide and chloride in photographic developer solutions
Determination of bromide and chloride in photographic developer solutions.
- AN-H-129Determination of weak bases in nonaqueous media through catalyzed thermometric endpoint titration (CETT)
Weak, organic bases that are soluble in nonaqueous solvents (including nonpolar solvents) are determined in glacial acetic acid using titration with strong acids, e. g., anhydrous perchloric acid or trifluoromethanesulfonic acid. The endpoint of such titrations can be determined thermometrically, insofar as a suitable thermometric endpoint indicator exists. The exceptional suitability of isobutyl vinyl ether (IBVE) as indicator has been demonstrated.
- AN-I-025Purity of lucigenin by nitrate determination – Fast and inexpensive determination by standard addition
Lucigenin is one of the most often used chemiluminescent reagents and might be used for e.g., the indication of the presence of superoxide anion radicals. Lucigenin is rather expensive to buy, however, its synthesis only includes a two stage synthesis starting from acridanone. The first stage includes an Nmethylation, the second forms the lucigenin chloride, which is finally transformed into lucigenin nitrate. To check the purity of the synthesized lucigenin, ion measurement can be applied using a nitrate selective electrode. This is a fast and inexpensive method compared to competing methods such as ion chromatography.
- AN-K-037Water in 2-methyl-5-mercaptothiadiazole
The water content of 2-methyl-5-mercaptothiadiazole is determined according to Karl Fischer using a special solvent mixture to prevent unwanted side reactions.
- AN-K-067Determination of the bromine index of aromatic hydrocarbons by coulometric titration according to ASTM D1492
The bromine index indicates the degree of unsaturation and relies on the simple addition of bromine to the double bond of alkenes. One mole of bromine is consumed for each mol of carbon-carbon double bond. The bromine index indicates the olefin content in aromatic hydrocarbons. This Application Note describes the determination by coulometric titration according to ASTM D1492.
- AN-K-07234433 HYDRANAL™ NEXTGEN Coulomat AG-FI
Karl Fischer reagents contain buffer substances (usually imidazole) since the reaction constant is dependent on the pH value. A constant pH therefore ensures the most repeatable results. In 2015, imidazole was classified by European Union the as a CMR (carcinogenic, mutagenic or toxic) substance and the statement H360D was added, stating possible harm to fertility or a fetus. Meanwhile, other reagents free of imidazole are available for purchase. This Application Note summarizes test measurements with 34433 HYDRANAL™ NEXTGEN Coulomat AG-FI.
- AN-N-030Nitrate, sulfate, and thiocyanate in additives for building materials
Determination of nitrate, sulfate, and thiocyanate in additives for building materials using anion chromatography with direct conductometric detection.
- AN-NIR-064Quality control of ammonium nitrate
Specialty chemicals have to fulfill multiple quality requirements. One of these quality parameters, which can be found in almost all certificates of analysis and specifications, is the moisture content. The standard method for the determination of moisture content is Karl Fischer titration.This method requires reproducible sample preparation, chemicals, and waste disposal. Alternatively, near-infrared spectroscopy (NIR) can be used for the determination of moisture content. With this technique, samples can be analyzed without any preparation and without using any chemicals.
- AN-O-028Citrate, ascorbate, and acetate in photographic developer solution
Determination of citrate, ascorbate, and acetate in photographic developer solution using ion-exclusion chromatography with suppressed conductivity detection.
- AN-S-228Anions in perfluorocarbon
Determination of fluoride, chloride, nitrate, sulfate, and oxalate in a perfluorocarbon material using anion chromatography with conductivity detection after chemical suppression.
- AN-S-352Determination of pyrophosphate and standard anions in 30% hydrogen peroxide (H2O2)
Pyrophosphate is used as a stabilizer in aqueous hydrogen peroxide solution. “Reagent grade” solutions may contain pyrophosphate in the higher mg/L range, while “electronic grade” hydrogen peroxide should be free of this stabilizer. Here the determination of pyrophosphate in a high purity H2O2 solution (30%) is performed applying Inline Preconcentration with Matrix Elimination (MiPCT-ME) and a Dose-in Gradient.
- AN-S-393Anions in hydrogen peroxide and ammonium hydroxide
The semiconductor industry requires high-purity or even ultrahigh-purity chemicals for the production of electronic components. The purity of the chemicals is crucial for the quality and efficient production of the parts. Here, hydrogen peroxide and ammonium hydroxide are analyzed applying traditional sample preparation methods like digestion and evaporation with subsequent reconstitution with ultrapure water. The received samples are injected applying intelligent Preconcentration Technique (MiPCT).
- AN-V-051Cadmium and lead in a herbicide
Determination of cadmium and lead in herbicide powder containing 37% copper after digestion.
- AN-V-160Palladium in an activator
The concentration of Pd in an activator bath is determined by polarography in ammonium chloride electrolyte.
- BWT-4901Raman Spectroscopy for Quick Quality Analyis of Diamond Membranes
Portable Raman is used to characterize the quality of diamond foils made by CVD processes.
- WP-047Tối ưu hóa quy trình clo-kiềm thông qua phân tích hóa học trực tuyến
Tài liệu White Paper này khám phá vai trò quan trọng của các phương pháp phân tích quy trình trực tuyến và trong dòng tiên tiến trong hoạt động sản xuất clo từ nước muối, nhấn mạnh những ưu điểm của chúng so với các phương pháp truyền thống.
- WP-048Utilizing online chemical analysis to optimize propylene oxide production
Propylene oxide (PO) is a major industrial product used in assorted industrial applications, mainly for the production of polyols (the building blocks for polyurethane plastics). Several production methods exist, with and without co-products. This white paper lays out opportunities to optimize PO production for safer and more efficient processes, higher quality products, and substantial time savings by using online process analysis instead of laboratory measurements.
- WP-054Boost efficiency in the QC laboratory: How NIRS helps reduce costs up to 90%
Underestimation of quality control (QC) processes is one of the major factors leading to internal and external product failure, which have been reported to cause a loss of turnover between 10–30%. As a result, many different norms are put in place to support manufacturers with their QC process. However, time to result and the associated costs for chemicals can be quite excessive, leading many companies to implement near-infrared spectroscopy (NIRS) in their QC process. This paper illustrates the potential of NIRS and displays cost saving potentials up to 90%.
- WP-063Khuyến nghị khi chuyển quy trình chuẩn độ thủ công sang chuẩn độ tự động
This white paper summarizes the steps involved in converting an existing manual titration procedure to semi-automated or automated titration procedures. It discusses topics such as selecting the right electrode and titration mode. For a better understanding, the discussion topics are illustrated with three examples.
- WP-066An introduction to ion chromatography mass spectrometry (IC-MS)
Ion chromatography mass spectrometry (IC-MS) is a powerful tool that can handle many challenging analytical tasks which cannot be performed adequately by IC alone. IC-MS is a robust, sensitive, and selective technique used for the determination of polar contaminants like inorganic anions, organic acids, haloacetic acids, oxyhalides, or alkali and alkaline earth metals. After separation of the sample components via IC, mass selective detection guarantees peak identity with low detection limits. The inclusion of automated Metrohm Inline Sample Preparation (MISP) allows not only water samples, but also chemicals, organic solvents, or post-explosion residues to be readily analyzed without need for extensive manual laboratory work. This White Paper explains the benefits of IC-MS over IC in certain cases, the hyphenation of IC and different MS systems, as well as related norms and standards.
- WP-068Khuyến cáo thẩm định phương pháp chuẩn độ
Mục đích của việc thẩm định quy trình phân tích là để chứng minh rằng nó phù hợp với mục đích sử dụng riêng. Các khuyến cáo về thẩm định phương pháp phân tích có thể được tìm thấy trong ICH Guidance Q2(R1) Validation of Analytical Procedures: Text and Methodology [1] và trong USP General Chapter <1225> Validation of Compendial Procedures. Mục đích của tài liệu này là để cung cấp một vài khuyến cáo về thẩm định phương pháp chuẩn độ.
- WP-072Định tính vật liệu 785 nm không có huỳnh quang với MIRA XTR DS
Trong White Paper này, bạn sẽ tìm hiểu về MIRA XTR DS – hệ thống Raman cầm tay nhỏ nhất, thông minh nhất, linh hoạt nhất với các thư viện lớn nhất hiện có trên thị trường! MIRA XTR DS có tất cả các lợi ích định tính Raman 785 nm: kích thước nhỏ gọn, công suất laser thấp, bảo quản mẫu, tuổi thọ pin dài... giờ đây có khả năng loại bỏ huỳnh quang. Ngoài ra, độ nhạy và độ phân giải được cải thiện so với các hệ thống 1064 nm. Điều này mở ra những khả năng mới cho Raman 785 nm, bao gồm các vật liệu có màu đậm, tá dược thông thường, vật liệu bất hợp pháp, v.v.