Tìm kiếm phụ kiện
DRP-RAMANPROBE638
Raman probe 638Reflection probe designed to be used with a single excitation 638 nm wavelength (up to 300 mW). Suitable to work with DropSens Raman cell for screen-printed electrodes (ref. RAMANCELL), Raman cell for conventional electrodes (ref. RAMANCELL-C) or with any conventional Raman set-up.
DRP-REFLECELL-C
UV-Vis/NIR spectroelectrochemical cell for conventional electrodesCell for UV-Vis/NIR spectroelectrochemical measurements with conventional electrodes.
DRP-RHNP-COL
Colloidal Rhodium Nanoparticles SolutionDRP-RPROBE-VIS-NIR
Reflection probe VIS-NIRReflection probe VIS-NIR designed to perform reflection experiments.
DRP-SBNP-PUR
Purified Antimony Nanoparticles SolutionDRP-SMAFC
SMA-FC adapterDRP-SMAFC105
SMA -FC fiber adapter 105 umDRP-SMAFC200
SMA -FC fiber adapter 200 umDRP-SNNP-PUR
Purified Tin Nanoparticles SolutionDRP-SPECELL4W-U20
Disposable well cell for 4W format screen-printed electrodesElectrochemical cells for easy and fast handling of 4W format screen-printed electrodes. Take advantage of their disposable, lightweight and quick-assembly design to handle large droplets and ensure good surface coverage and sample sealing.
DRP-SPECELL8W-U20
Disposable well cell for 8W format screen-printed electrodesElectrochemical cells for easy and fast handling of 8W format screen-printed electrodes. Take advantage of their disposable, lightweight and quick-assembly design to handle large droplets and ensure good surface coverage and sample sealing.
DRP-SPECELL8X-U20
Disposable well cell for 8X format screen-printed electrodesElectrochemical cells for easy and fast handling of 8X format screen-printed electrodes. Take advantage of their disposable, lightweight and quick-assembly design to handle large droplets and ensure good surface coverage and sample sealing.
DRP-SPECELL-U75
Disposable well cell for screen-printed electrodesElectrochemical cells for easy and fast handling of screen-printed electrodes. Take advantage of their disposable, lightweight and quick-assembly design to handle large droplets and ensure good surface coverage and sample sealing.
DRP-SYNCONN96X
Automatic controller for CONNECTOR96XSYNCONN96X is an automatic controller of CONNECTOR96X that allows executing the assays sequentially without the need of employing the manual rotating selectors at the CONNECTOR96X.
DRP-TFIBER-VIS-NIR
Transmission fiber VIS-NIRTransmission fiber VIS-NIR designed to perform transmission experiments
DRP-TLCELL
Thin-layer cell for screen-printed electrodesThin-layer electrochemical cell for screen-printed electrodes with 2mm banana direct connections
DRP-TLFCELL
Thin-layer flow electrochemical cellThin film flow cell for use with ceramic SPEs with the detection zone in the center of the strip. It allows the study of different parameters under flow conditions.
DRP-TLFCLRAMANCELL
Raman flow-cell for Thin-layer flow-cell integrated screen-printed electrodesDRP-TRANSPACK-VIS-UV
Pack for transmission experiments with SPEs (Includes: 1 x TRANSCELL, 1 x CLENS, 1 x TFIBER-VIS-UV, 1 x RPROBE-VIS-UV and 1 x CAST-P)Pack designed for those researchers insterested in performing transmision UV-VIS experiments with screen-printed electrodes and SPELEC instrument
DRP-TUBEB-U12
PVC tube for peristaltic pump – 1,651 mm inner diameterPVC tube for peristaltic pump – 1.651 mm inner diameter
DRP-TUBEO-U12
PVC tube for peristaltic pump – 0,889 mm inner diameterPVC tube for peristaltic pump – 0.889 mm inner diameter
DRP-TUBER-U12
PVC tube for peristaltic pump – 1,143 mm inner diameterPVC tube for peristaltic pump – 1.143 mm inner diameter
DRP-TUBEY-U12
PVC tube for peristaltic pump – 1,422 mm inner diameterPVC tube for peristaltic pump – 1.422 mm inner diameter
DRP-USBFLOATING
USB floating cableThe floating USB cable is a galvanic isolation accessory that connected to your instrument will allow you to work in “floating mode” instead of “grounded mode”
DRP-VKIT
Instruments verification kits for µStat 300 and µStat 400Kit for verifying the correct performance of instruments: μStat 300 and μStat 400
DRP-VKITECL
Instruments verification kits for µStat ECL and SpectroECLKit for verifying the correct performance of instruments: μStat ECL and SpectroECL. With this kit you will be able to perform electrochemical and optical verification.
DRP-VKITMULTI
Instruments verification kits for µStat 4000P, µStat 4000, µStat 8000P and µStat 8000Kit for verifying the performance of instruments: μStat4000P, μStat 4000, μStat 8000P and μStat 8000. You will be able to verify each independent channel and the multichannel mode of your equipment.
DRP-VKITSPELEC
Instruments verification kits for SPELEC and SPELEC1050Kit for verifying the performance of instruments: SPELEC and SPELEC 1050. With this kit, you will be able to perform electrochemical and optical verification.
DRP-VKITSPELECNIR
Instruments verification kit for SPELEC NIRKit for verifying the correct performance of SPELECNIR instrument. With this kit, you will be able to perform electrochemical and optical verification.
DRP-VKITSPELECRAMAN
Instruments verification kit for SPELEC RAMANKit for verifying the correct performance of SPELECRAMAN instrument. With this kit, you will be able to perform electrochemical and optical verification.
ECAT.COMPACT.S
ECAT compact packageMetrohm Autolab offers and ECAT compact package that offers electrochemical instrumentation and accessories with an industry-leading 3-year warranty as standard. With a compact PGSTAT204 equipped with a dual-mode bipotentiostat module.The Autolab ECAT compact package comes with free NOVA 2 software that provides built-in Levich and Koutecky – Levich analysis methods for fast and easy data analysis. Included in the package is also a Rotating Ring Disk Electrode (RRDE) that is high precision with an ultra-low noise electrode rotation from 100 to 10,000 RPM. A complete RRDE electrochemical cell is also included in the package.Possible applications include: electrocatalyst material testing, mechanistic information,: detection of intermediates via collection and shielding experiments (RRDE), electrochemical kinetics studies, mass-transport properties with forced convection conditions.This package offers high-quality standard measurements including those under forced convection conditions.
ECD.S
Low current amplifier moduleThe lowest current range available on the standard Autolab is 10 nA. At this current range, the Autolab has a current resolution of 30 fA. When doing measurements on micro-electrodes sometimes even higher resolution is needed. Originally designed for electrochemical detection in HPLC and FIA, the ECD module makes the measurement of such low currents possible.The ECD module provides 2 additional current ranges of 1 nA and 100 pA giving a minimum current resolution of 0.3 fA. The ECD module also has a built in third order Sallen-Key filter, with 3 RC-time constants that help to filter out noise.
ECI10M.S
High frequency impedance spectroscopyThe ECI10M extends the measurable range for electrochemical impedance spectroscopy to a maximum of 10 MHz.The ECI10M consists of a module, installed in the Autolab potentiostat/galvanostat and coupled to the FRA32M module and an external interface designed to be placed in close proximity of the electrochemical cell in order to minimize the effects from the electrode cables.The small form factor of the external interface allows measurements in a glove box or Faraday cage.The ECI10M uses the Automatic Amplitude Correction algorithm (AAC) to ensure that the amplitude applied on the cell corresponds to the required amplitude at all times, thus maximizing the resolution while respecting the linearity and stability conditions during the measurement.
ECN.S
Electrochemical noise moduleElectrochemical noise (ECN) is an in-situ technique for measuring these localized corrosion processes on bare or coated metal samples. During measurements with the ECN module no external perturbation (potential or current) is applied to the electrode. The potential and current signals are measured as a function of time.The accompanying analysis software allows the current and potential versus time data to be analyzed using Fast Fourier Transform (FFT). The software also provides several filtering and mathematical methods for treating electrochemical noise signals.
EQCM.CELL.S
EQCM complete cell including coverEQCM complete cell including cover
EQCM.MAC.204.S
Electrochemical Quartz Crystal Microbalance moduleThe EQCM module provides the means to perform Electrochemical Quartz Crystal Microbalance experiments. The EQCM module measures a mass change per unit area by recording the change in resonant frequency of a quartz crystal oscillator.Measurements in the sub μg/cm2 are possible. The EQCM can be fitted with 6 MHz, AT-cut crystals.The EQCM module is supplied with a suitable electrochemical cell, reference and counter electrode and two 6 MHz gold-coated crystals.
EQCM.S
Electrochemical Quartz Crystal Microbalance moduleThe EQCM module provides the means to perform Electrochemical Quartz Crystal Microbalance experiments. The EQCM module measures a mass change per unit area by recording the change in resonant frequency of a quartz crystal oscillator.Measurements in the sub μg/cm2 are possible. The EQCM can be fitted with 6 MHz, AT-cut crystals.The EQCM module is supplied with a suitable electrochemical cell, reference and counter electrode and two 6 MHz gold-coated crystals.
FAR.CAGE.LRG
Large Faraday CageThe Autolab Faraday cage has been designed to allow the users to protect their electrochemical cell setup from electro-magnetic interference from external sources such as computer monitors, other instruments in the lab or power lines.In many cases the main source of external electrical interference is the line frequency (50/60 Hz) which can corrupt electrochemical data, particularly when small signals are being measured. An earth terminal is available in the Faraday cage to connect to the Autolab to prevent ground loops.External dimensions: (WxDxH) 38x30x60 cm3
FAR.CAGE.LRG
Large Faraday CageThe Autolab Faraday cage has been designed to allow the users to protect their electrochemical cell setup from electro-magnetic interference from external sources such as computer monitors, other instruments in the lab or power lines.In many cases the main source of external electrical interference is the line frequency (50/60 Hz) which can corrupt electrochemical data, particularly when small signals are being measured. An earth terminal is available in the Faraday cage to connect to the Autolab to prevent ground loops. External dimensions: (WxDxH) 38x30x60 cm3
FAR.CAGE.S
Faraday CageThe Autolab Faraday cage has been designed to allow the users to protect their electrochemical cell setup from electro-magnetic interference from external sources such as computer monitors, other instruments in the lab or power lines.In many cases the main source of external electrical interference is the line frequency (50/60 Hz) which can corrupt electrochemical data, particularly when small signals are being measured. An earth terminal is available in the Faraday cage to connect to the Autolab to prevent ground loops.
FI20.S
Analog filter and integrator moduleThe FI20 filter and integrator module allows the Autolab users to do coulometric and chrono-coulometric experiments. The analog integrator gives you the possibility to measure charge instead of current and can be used both in cyclic voltammetry as well as in potential step experiments.With this module it is easy to separate the capacitive current from the faradaic current. In addition the integrator is effective in reducing signal noise by averaging it out.The third order Sallen-Key filter with selectable RC-times between 0 and 500 ms, can be used to filter out noise.The filter of the FI20 module is also useful in cases where the background noise (50 or 60 Hz for example) cannot be removed by using measures like a Faraday cage.
FLAT.CELL.S
Flat cellThe Autolab flat cell is a corrosion cell suitable for measurements on very large flat samples, up to 17 cm² in size. The cell is supplied with a reference electrode, a stainless steel counter electrode and a gas purging tube.
FLAT.CLAMP
Clamp for fixing the vessel to the flat sample and platformFLAT.COUNTER
Flat cell steel counter electrodeFLAT.GAS
Flat cell gas inletFLAT.PLATFORM
Sample platform for large flat samples with 4 mm fem. bananaFLAT.PLATFORM.CMPL.S
Flat Sample PlatformComplete Flat sample platform for large, flat samples.Keywords: Corrosion cell, linear polarization, Tafel, corrosion rate, flat samples, salt spray
FLAT.RING
Flat cell O-ring (set of 5)FLAT.TOP
Flat cell PTFE top coverFLAT.VESSEL
Flat cell vesselFRA32M.MAC.204.S
Electrochemical Impedance Spectroscopy ModuleThe FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.
FRA32M.S
Electrochemical impedance spectroscopy moduleThe FRA32M provides the means to perform impedance and electrochemical impedance measurements in combination with the Autolab. This module allows one to perform both potentiostatic and galvanostatic impedance measurements over a wide frequency range of 10 µHz to 32 MHz (limited to 1 MHz in combination with the Autolab PGSTAT). In addition to the classical EIS, the NOVA software also allows the users to modulate other outside signals such as rotation speed of a rotating disk electrode or the frequency of a light source to perform Electro-hydrodynamic or Photo-modulated impedance spectroscopy.The FRA32M module comes with a powerful fit and simulation software for the analysis of impedance data.
GAS.INLET.FRIT
RRDE cell gas purgeTwo way gas purge tube for the Autolab RRDE and 1L Corrosion Cell.
IME663.101.S
Interface for Metrohm 663 VA StandInterface for Metrohm 663 VA Stand
IME663.S
Interface for Metrohm 663 VA StandInterface for Metrohm 663 VA Stand.
LOAD.INT.S
Dynamic load interfaceThe Electronic load interface is a generic interface that can be used to control third party electronic loads or power supplies, in order to perform electrochemical measurements at very high power. With a programmable electronic load, the Autolab is able to sink very high currents, up to the limit of the electronic load. With a programmable power supply, the Autolab is able to source very high currents, up to the limit of the power supply.
MBA.S
Dual mode bipotentiostat moduleThe MBA.S is an additional bipotentiostat module which can be installed into a MultiBA (MBA) Autolab potentiostat/galvanostat adding an additional working electrode to the MBA instrument. A maximum of 5 MBA.S modules together with one FRA32M.S module can be installed in one MBA instrument.
MUX.MAC.204.S
Multiplexer moduleThe MUX module series allows you to perform electrochemical experiments on multiple cells or multiple working electrodes, sequentially. The cell to perform measurement on can be selected either manually or automatically using the sequencing option of NOVA. Metrohm Autolab offers two types of MUX modules.• MUX.MULTI4 - Used to multiplex all four connections from the Autolab. This allows sequential measurements on complete electrochemical cells, up to 64 cells with increments of 4.• MUX.SCNR16 - Used to multiplex the working electrode connection of the Autolab. This allows sequential measurements on cells that share the same counter, reference and sense electrode but different working electrode, up to 255 different working electrodes with increments of 16.• MUX.SCNR8 - Used to multiplex the reference and sense electrode connections of the Autolab. This allows sequential voltage sensing across different electrochemical cells, up to 128 cells with increments of 8.
MUX.MULTI4.S or MUX.SCNR16.S or MUX.SCNR8.S
Multiplexer moduleThe MUX module series allows you to perform electrochemical experiments on multiple cells or multiple working electrodes, sequentially. The cell to perform measurement on can be selected either manually or automatically using the sequencing option of NOVA. Metrohm Autolab offers two types of MUX modules.MUX.MULTI4 - Used to multiplex all four connections from the Autolab. This allows sequential measurements on complete electrochemical cells, up to 64 cells with increments of 4.; MUX.SCNR16 - Used to multiplex the working electrode connection of the Autolab. This allows sequential measurements on cells that share the same counter, reference and sense electrode but different working electrode, up to 255 different working electrodes with increments of 16.; MUX.SCNR8 - Used to multiplex the reference and sense electrode connections of the Autolab. This allows sequential voltage sensing across different electrochemical cells, up to 128 cells with increments of 8.;
MUX.S
Multiplexer moduleThe MUX module series allows you to perform electrochemical experiments on multiple cells or multiple working electrodes, sequentially. The cell to perform measurement on can be selected either manually or automatically using the sequencing option of NOVA. Metrohm Autolab offers two types of MUX modules.MUX.MULTI4 - Used to multiplex all four connections from the Autolab. This allows sequential measurements on complete electrochemical cells, up to 64 cells with increments of 4.; MUX.SCNR16 - Used to multiplex the working electrode connection of the Autolab. This allows sequential measurements on cells that share the same counter, reference and sense electrode but different working electrode, up to 255 different working electrodes with increments of 16.; MUX.SCNR8 - Used to multiplex the reference and sense electrode connections of the Autolab. This allows sequential voltage sensing across different electrochemical cells, up to 128 cells with increments of 8.;
NOVA.x
NOVA installation USB stickNOVA installation USB stick, including NOVA license.
pX1000.LEMO.BAN
pX1000 V+/V- cablesDifferential input cables for the pX1000 module. Two cables are provided, V+ and V-.
pX1000.LEMO.CVR
pX1000 input coverCover for unused inputs of the pX1000 module.
pX1000.MAC.204.S
Voltage and pH measurement moduleThe pX1000 allows the measurements of pH or pX values during electrochemical experiments. This module also provides an additional Pt1000 input which allows recording of the temperature during the experiments, either through a Pt1000 sensor or through a combined pH/Pt1000 sensor. The temperature measurement allows automatic pH corrections.The pX1000 module can also be used as an additional differential electrometer, with the same specifications as the main Autolab electrometer. The pX1000 module is compatible with the Metrohm pH and temperature sensors. The user can connect any pH, pX or ‘double’ electrode to the pX1000 module. In case an electrode other than a pH electrode is used, the output is given as the voltage difference that is measured between the electrodes making it possible to connect a detection electrode to perform coulometric titration. The pX1000 module also works as an independent pH meter.
pX1000.S
Voltage and pH measurement moduleThe pX1000 allows the measurements of pH or pX values during electrochemical experiments. This module also provides an additional Pt1000 input which allows recording of the temperature during the experiments, either through a Pt1000 sensor or through a combined pH/Pt1000 sensor. The temperature measurement allows automatic pH corrections.The pX1000 module can also be used as an additional differential electrometer, with the same specifications as the main Autolab electrometer. The pX1000 module is compatible with the Metrohm pH and temperature sensors.The user can connect any pH, pX or ‘double’ electrode to the pX1000 module. In case an electrode other than a pH electrode is used, the output is given as the voltage difference that is measured between the electrodes making it possible to connect a detection electrode to perform coulometric titration. The pX1000 module also works as an independent pH meter.
RCE.EL
RCE.ELRotating cylinder electrode for 12 mm OD cylinders. Cylinder insert in NOT included. Available cylinder materials: carbon steel 1018 (RCE.CYL.CS1018) and stainless steel 304 (RCE.CYL.SS304)
RHD.CAP.GC3
Cap with exchangeable electrode Electrode Tips (ET)Exchangeable electrode pressed in PEEK made of various materials with diverging diameters and lengths.
RHD.CLEAN.KIT
Cleaning and Polishing KitThe cleaning and polishing kit contains all tools required to perfectly clean the measuring cells of sample residue, and to polish especially the platinum crucibles to mirror-like finish. The kit contains a multifunctional rotary tool.
RHD.HCBAS.CLOSED.S
Autolab Microcell HC Basic Package closedAutolab Microcell HC Basic Package closed features a temperature-controlled cell stand as the basis for all rhd instruments measuring cells.The cell stand contains the peltier element for active heating and cooling of the measuring cell. It allows the hassle-free establishment of the cell connections to the potentiostat.This package includes:1 Cell holder Autolab Microcell HC; 1 temperature controller 3216; 1 Heat conducting compound; 1 Serial connection kit; 1 Adapter box BNC - banana; All required connection cables and tools; Measuring cells sold separately.
RHD.TSC1600.CLOSED
Measuring Cell TSC 1600 ClosedThe TSC 1600 Closed is an closed measuring cell intended for investigating liquid electrolytes. This measuring cell has a 1.6 mL platinum crucible as sample container. For smaller sample volume, please use the TSC 70 Closed cell. This cell is airtight and thus shielded against the atmosphere and can be used with moisture-sensitive samples.
RHD.TSCBATT.ADVANCED
Measuring Cell TSC Battery ExpandedThe TSC Battery Expanded is a closed measuring cell intended for assembling half or full battery or supercap cells with e.g. active materials and separators. It is also suitable for investigating solid or gel-like samples in contact with metal electrodes in a plat/plate geometry. You have flexibility with cell configuration either two or three electrode measurements can be performed by inserting a microreference electrode from the side. The standard variant contains flat metal electrodes. For current collectors designed for using elemental lithium as electrode material please refer to the extended variant.
RHD.TSCSPECTRO
Measuring Cell TSC SpectroThe TSC Spectro cell is a closed measuring cell intended for performing spectro-electrochemistry experiments. It comes with a platinum gauze electrode located at the focal point of the sensing light beam entering through adjustable side windows. Both two and three electrode measurements can be performed by inserting a microreference electrode from the side. This cell is airtight and thus shielded against atmosphere and can be used with moisture-sensitive samples.Cell Materials in contact with sample: PEEK, Platinum, Glassy Carbon, EPDM, FFKM
RRDE.CAP
RRDE cell lidTeflon lid with seven conical fittings for the Autolab RRDE Cell.
RRDE.CELL.CPL.S
Autolab Electrocatalysis RRDE cellThe Autolab RRDE cell is a complete electrochemical cell designed for experiments under forced convection with the Autolab RRDE (or Autolab RDE2). The kit consists of a glass vessel with a volume of 300 mL, fitted with a thermostatic jacket for temperature control.All the parts that can come in contact with the solution can be cleaned in aggressive conditions, making the cell suitable for typical electrocatalysis experiments or sensitive interfacial electrochemistry measurements.
RRDE.CLAMP
RRDE cell clampMetal cell stand holder for the Autolab RRDE Cell.
RRDE.HOSE.CONN
RRDE cell hose connectorSet of adapters for connecting an external waterbath to the Autolab RRDE Cell for temperature control.
RRDE.ORING.SIL
RRDE cell sealTeflon-coating o-ring for the Autolab RRDE Cell.
RRDE.RING.NYLON
RRDE cell clamping ringHolding ring for the Autolab RRDE Cell.
RRDE.STOPPER
RRDE cell glass stopperSet of glass stoppers for the Autolab RRDE Cell.
RRDE.THERM.ADAPT
RRDE cell thermometer adapterThermometer adapter for the Autolab RRDE Cell.
RRDE.VESSEL
RRDE cell vesselGlass vessel of the Autolab RRDE Cell.
SCAN250.S
True linear scan generator moduleWhen the processes exhibit very fast transient behavior, such as hydrogen adsorption, digital sweep can lead to loss of information regarding the adsorption process. The SCAN250 module, which has the capability of applying a true analog sweep to the sample, was specially designed to overcome this problem. The true linear scan rate range is from 10 mV/s to 250 kV/s. The SCAN250 module in combination with ADC10M is a very powerful tool for studying fast transients.
VOLT.MULT.S
Voltage MultplierThe voltage multiplier is an extension that can be placed in series with the differential amplifier of the Autolab to extend the measurable voltage range to a maximum of 100 V. This can be used to perform electrochemical measurements on battery and fuel cell stacks.