- 8.000.6021Water analysis
A complete tap water analysis includes the determination of the pH value, the alkalinity and the total water hardness. Both the pH measurement and the pH titration by means of a standard pH electrode suffer from several drawbacks. First, the response time of several minutes is too long and, above all, the stirring rate significantly influences the measured pH value. Unlike these standard pH electrodes, the Aquatrode Plus with its special glass membrane guarantees rapid, correct and very precise pH measurements and pH titrations in solutions that have a low ionic strength or are weakly buffered. Total water hardness is ideally determined by a calcium ion-selective electrode (Ca ISE). In a complexometric titration, calcium and magnesium can be simultaneously determined up to a calcium/magnesium ratio of 10:1. Detection limits for both ions are in the range of 0.01 mmol/L.
- AB-101銅イオン選択性電極による錯滴定(自動滴定装置)
このアプリケーションでは、銅イオン選択性電極(Cu-ISE)を用いたEDTA滴定による金属イオンの電位差滴定を紹介します。水の硬度、希土類元素(REE)、鉱石、電気めっき浴などに含まれる各種金属イオンの高精度な定量が可能です。
- AB-125Simultaneous determination of calcium, magnesium, and alkalinity by complexometric titration with potentiometric or photometric indication in water and beverage samples
This bulletin describes the determination of calcium, magnesium, and alkalinity in water by complexometric titration with EDTA as titrant. It is grouped into two parts, the potentiometric determination and the photometric determination.There are multiple definitions of the different types of water hardness. In this Application Bulletin, the following definitions are used: alkalinity, calcium hardness, magnesium hardness, total hardness, and permanent hardness. Explanations of these definitions and other expressions are provided in the Appendix.Determination of alkalinity during the photometric part is carried out in a separate acid-base titration before the complexometric titration of calcium and magnesium in water. Permanent hardness can be calculated from these values. The determination of calcium and magnesium in beverages (fruit and vegetable juices, wine) is also described.The photometric part includes the determinations of total and calcium hardness and thereby indirectly magnesium hardness using Eriochrome Black T and calconcarboxylic acid as indicators (in accordance with DIN 38406-3).
- AB-178完全自動の水質分析
電気伝導度、pH値、p値およびm値 (アルカリ度)、塩化物含有量、カルシウムおよびマグネシウム硬度、総硬度、ならびにフッ化物含有量などといったか物理的および化学的パラメータの測定は、水質評価において必要不可欠です。この bulletin では、上記のパラメータを、一度の分析実行でいかに測定できるかが説明されています。水質分析においてさらに重要なパラメータは、過マンガン酸塩指数 (PMI) および化学的酸素要求量 (COD) です。そのため、この Bulletin では、EN ISO 8467に準じたPMIの完全自動測定、ならびにDIN 38409-44に準じたCODの測定についても説明しています。
- AB-221水質分析の標準的な方法
この会報は、水分析の分野からの標準的な方法の調査を提供します。また、それぞれの決定に必要な分析機器と、対応するメトロームアプリケーション速報およびアプリケーションノートへの参照もあります。次のパラメータが処理されます:電気伝導率、pH値、フッ化物、アンモニウムおよびケルダール窒素、イオンクロマトグラフィーによる陰イオンおよび陽イオン、ボルタンメトリーによる重金属、化学酸素需要(COD)、水の硬度、遊離塩素も他のいくつかの水の成分として。
- AN-PAN-1036Online determination of alkalinity and hardness in process and make up water for beer production
Beer is a popular beverage consumed by millions of people for enjoyment, despite its humble beginnings as a water purification technique in pre-modern times. Brewing beer requires large amounts of water which must adhere to strict alkalinity, hardness, and pH parameters to ensure uniformity in flavor and appearance between each batch. Alkalinity is introduced by carbonates and hydroxides in water which raise and buffer the pH. Hardness, balanced to a large degree by the alkalinity, comes from Ca and Mg ions, mainly present as hydrogen carbonates. Depending on the concentration ranges, the 2035 Process Analyzer or the 2060 Process Analyzer are ideally suited for the fully automatic execution of these important analyses, as well as additional parameters like pH or conductivity. These process analyzers can signal the plant’s distribution system to correct the water chemistry, ensuring consistent product quality. In addition to alkalinity and water hardness, numerous other parameters can also be determined (pH, conductivity, etc.).
- AN-S-387TitrICによる包括的な水質分析
TitrIC flex IIシステムは、すべてのキーパラメータの完全自動分析のために、滴定装置とイオンクロマトグラフ組み合わせたシステムです。これには、pH、電気伝導度、硬度、陰イオン、陽イオン、イオンバランスの計算が含まれます。1台のシステムによる包括的な水質分析です。
- AN-T-074全自動分析システムによる水道水中の電導度・pH・アルカリ度・硬度測定
水道水の電導度、pH値、アルカリ度、硬度を1回の分析で自動測定する全自動システムを解説します。815 Robotic USB Sample Processor XLと905 Titrando、856 Conductivity Moduleによる電位差滴定を中心に、前処理からセンサー校正まで自動化した分析手法を紹介します。
- AN-T-076全自動分析による水道水中電気伝導度・pH・アルカリ度・硬度・塩化物測定
この技術資料では、全自動分析による水道水中の電気伝導度・pH・アルカリ度・硬度・塩化物の同時測定法を解説します。具体的には、標準塩酸・EDTA・硝酸銀を用いた電位差滴定と電気伝導度・pHの直接測定を組み合わせ、前処理から洗浄まで完全自動化された1試料15分未満・高い再現性の分析結果について紹介します。
- AN-T-084光度滴定法による水試料中の全硬度・カルシウム硬度・マグネシウム硬度の全自動測定
光度滴定センサーOptrode(610 nm)を用いて、水試料中の全硬度、カルシウム硬度、マグネシウム硬度を測定を紹介したアプリケーション。
- AN-T-131【技術資料】Cu-ISEを用いた電位差滴定による水中Ca・Mg・硬度測定
この技術資料では、Cu-ISEを用いた電位差滴定による水中カルシウム・マグネシウム・全硬度の測定法を解説します。具体的には、EDTA・EGTA標準液による滴定とCu-EDTA/Cu-EGTA指標物質による終点検出の仕組みや、従来の光度法に比べて高い客観性と再現性が得られる分析結果について紹介します。
- AN-T-205【技術資料】複数項目の水質分析をOIMNISシステムで完全自動滴定
電気伝導度、pH値、アルカリ度、カルシウム硬度、マグネシウム硬度、ならびに総硬度などといった物理的および化学的パラメータの測定は、水道水の水質検査において必要不可欠です。このような必須の複数の水質検査項目をOMNIS滴定システムなら1つのシステム内で並行して自動測定できます。
- TA-044水と土壌の分析におけるpH値、導電率、滴定
地球の人口の急速な増加は、エネルギーと資源の消費と消費者製品と化学物質の生産の大幅な増加をもたらしました。現在、1700万の化合物が市場に出回っていると推定されており、そのうち10万が大規模な工業規模で生産されています。これらの多くは環境に入ります。これにより、高感度の分析手順と高性能の分析機器が求められています。pH値、導電率、および酸素要件は、水と土壌の分析における重要な特性です。これらの最初の2つは迅速に決定できます。 3つ目は、使用される滴定が多数の単一測定で使用される滴定でもあります。この記事では、水と土壌の分析におけるいくつかの重要な標準準拠の決定について説明します。
- WP-011可視-近赤外分析法(Vis-NIR塗料)およびコーティング剤の耐久性試験
塗料やコーティング剤の業界では、厳格な規制と複雑な製品の増加がテストの複雑さを増加させました。そのため製造メーカーは、より強力で安全で耐久性の高い分析手法が求められています。可視-近赤外分析法(Vis-NIR)による試験は、多くの湿式化学分析法と比べて、耐久性や費用効果の高い代替法です。この技術資料では、可視-近赤外分析法(Vis-NIR)が、経済面および環境保護の面で、塗料やコーティング剤の製造および生産における様々な分析工程を改善する方法を解説しています。キーワード: 試験、耐久性、VOC、塗料、コーティング剤、接合剤、合成樹脂、添加剤、顔料、溶媒
- WP-090ASTM D8192による水の硬度測定の自動化
水中に自然に存在するカルシウムおよびマグネシウムは、設備のチューブや配管を詰まらせる主な原因であり、場合によっては設備の故障やプロセス効率の低下につながります。パイプラインの問題やプロセス、設備のシャットダウンを避けるためにも、水の硬度(カルシウムおよびマグネシウム)は、頻繁に測定されなければいけません。 この資料では、ASTM D8192準拠による水の硬度測定を測定しています。自動滴定装置に光度滴定電極を使用して、カルシウムとマグネシウムの総量を測定しています。